    900VPR-2-280/520V-CU - Digital 3Ø Self-Powered Voltage / Phase / Frequency Protection Relay|Process Controllers
    900VPR-2-280/520V-CU - Digital 3Ø Self-Powered Voltage / Phase / Frequency Protection Relay|Process Controllers
    900VPR-2-280/520V-CU - Digital 3Ø Self-Powered Voltage / Phase / Frequency Protection Relay|Process Controllers
    900VPR-2-280/520V-CU - Digital 3Ø Self-Powered Voltage / Phase / Frequency Protection Relay|Process Controllers
    900VPR-2-280/520V-CU - Digital 3Ø Self-Powered Voltage / Phase / Frequency Protection Relay|Process Controllers
    900VPR-2-280/520V-CU - Digital 3Ø Self-Powered Voltage / Phase / Frequency Protection Relay|Process Controllers

    900VPR-2-280/520V-CU - Digital 3Ø Self-Powered Voltage / Phase / Frequency Protection Relay

    900VPR-2-280/520V-CU

    900VPR-2-280/520V-CU - Digital 3Ø Self-Powered Voltage / Phase / Frequency Protection Relay
    - Backlit Liquid Crystal Display


    Features

    •  3Ø - 3 Wire, 3Ø - 4 Wire Input

    • Self-powered

    • Monitors under-voltage, Over-voltage, Under-frequency, Over-frequency, Phase asymmetry, Phase failure and Phase sequence

    • True RMS measurement

    • Power ON delay, Trip time delay, and Recovery time delay

    • Adjustable switching Hysteresis

    • Two separate alarm relays

    • LCD

    • Din Rail mount

    • Size: 35mm (Width)

     DATA Sheet Link

    < Product photo may vary depending on part number selection.

     

    Analog / Digital Protection Relays

    Protection
    Altech is pleased to offer a variety of protection relays covering:

    • Phase Monitoring

    • Voltage Monitoring

    • Current Monitoring

    • Frequency Monitoring

    Current Leakage / Ground Fault Monitoring Protection relays help to maintain systems and ensure that proper action is taken when a fault is detected. Such functions help to preserve productivity and operational effectiveness of integral components. 

    Process Controllers - Supply Voltage
    280-520V AC
    Process Controllers - LED Indication
    LED 1: Power On, LED 2: Relay 1, LED 3: Relay 2
    Process Contollers - Input Voltage
    Self Powered 280-520 V AC
    Process Controllers - Input Measurement
    Under Voltage / Over Voltage / Under Frequency / Over Frequency / Phase Asymmetry / Phase Failure / Phase Sequence
    Process Controllers - Trip Setting
    Under Voltage: 280- 520 V AC [L-L] (3Ø-3 wire) 160-300 V AC [L-N] (3Ø-4 wire), Over Voltage: 280-520 V AC [L-L] (3Ø-3 wire) 160-300 V AC [L-N](3Ø-4 wire)*Download Data Sheet for more information
    Process Controllers - Main Output
    SPDT -2 C/O - NO: 5A, 250 V AC and NC:3A, 250 V AC
    Process Controllers - Trip Time Settings
    Power ON Delay: 2-99.9 sec / Trip Time Delay: 0-99.9 sec / Recovery Time Delay: 0-99.9 sec / Response Time: greater than 200ms
    Process Controllers - Hysteresis
    Current: 0.1-99.9A
    Process Controllers - Reset
    Auto/Manual (Selectable)
    Process Controllers - Operating Temperature
    0 to 50°C (32 to 122°F)
    Process Controllers - Storage Temperature
    -20 to 75°C (-4 to 167°F)
    Process Controllers - Humidity (Non-Condensing)
    95% Relative Humidity
    Process Controllers - Weight
    135 grams (.31 lbs)
    Process Controllers - Display Type
    Liquid Crystal Display
    Process Controllers - Digits
    1 row of 3 digits
    Process Controllers - Latching
    Selectable
    Process Controllers - Electrical Connection
    3Ø-3 wire, 3Ø- 4 wire
    Process Controllers - Protection Level
    IP50 (for faceplate), IP30 (for housing), IP20 (for terminals)
    Process Controllers - Measuring Range
    280 - 520V AC [L-L]; 160 - 300V AC [L-N]
    Process Controllers - Voltage
    +/-1%
    Process Controllers - Alarm Indications
    Trip
    Process Controllers - Frequency
    +/-0.3 Hz
    Process Controllers - Time Setting
    +/- 5% of setting, + 200ms
    900VPR-2-280/520V-CU
    No reviews
    Product added to wishlist
    Product added to compare.

    This site uses Cookies.