×
    600VPR-170/290-CU - Analog / Digital Protection Relay|Process Controllers
    600VPR-170/290-CU - Analog / Digital Protection Relay|Process Controllers
    600VPR-170/290-CU - Analog / Digital Protection Relay|Process Controllers
    600VPR-170/290-CU - Analog / Digital Protection Relay|Process Controllers
    600VPR-170/290-CU - Analog / Digital Protection Relay|Process Controllers
    600VPR-170/290-CU - Analog / Digital Protection Relay|Process Controllers

    600VPR-170/290-CU - Analog / Digital Protection Relay

    600VPR-170/290-CU

    600VPR-170/290-CU - Analog / Digital Protection Relay
    - Analog 3Ø Self Powered Voltage / Phase Protection Relay, LED Indication


    Features

    • 3Ø - 3 Wire Input

    • Self Powered

    • Monitors Under Voltage, Over Voltage, Phase Sequence and Phase Failure

    • Trip time delay (T); 0.2 to 10 sec

    • Slim, Space Saving Design

    • DIN Rail Mount

    • Size: 17.5mm (width)

     DATA Sheet Link

    < Product photo may vary depending on part number selection.

     

    Analog / Digital Protection Relays

    Protection
    Altech is pleased to offer a variety of protection relays covering:

    • Phase Monitoring

    • Voltage Monitoring

    • Current Monitoring

    • Frequency Monitoring

    Current Leakage / Ground Fault Monitoring Protection relays help to maintain systems and ensure that proper action is taken when a fault is detected. Such functions help to preserve productivity and operational effectiveness of integral components. 

    Process Controllers - Supply Voltage
    170 to 290V AC
    Process Controllers - LED Indication
    Relay ON, Power ON
    Process Contollers - Input Voltage
    Self Powered 170-290V AC
    Process Controllers - Input Measurement
    Under Voltage/ Over Voltage / Phase Failure / Phase Sequence
    Process Controllers - Trip Setting
    Under Voltage: 170-224V AC / Over Voltage: 236-290V AC
    Process Controllers - Trip Delay
    0.2 - 10 sec
    Process Controllers - Main Output
    SPDT - 1 C/O - NO: 5A, 250 V AC and NC:3A, 250 V AC
    Process Controllers - Trip Time Settings
    Power ON Delay: 0.4 sec / Trip Time Delay: 0.2-10 sec
    Process Controllers - Reset
    Auto reset on removal of fault condition
    Process Controllers - Power Consumption
    20VA max
    Process Controllers - Trip Voltage
    +/- 5% of Full Scale
    Process Controllers - Trip Time
    +/-5% of Full Scale
    Process Controllers - Operating Temperature
    0 to 50°C (32 to 122°F)
    Process Controllers - Storage Temperature
    -20 to 75°C (-4 to 167°F)
    Process Controllers - Humidity (Non-Condensing)
    95% Relative Humidity
    Process Controllers - Weight
    62 grams (.13lbs)
    600VPR-170/290-CU
    No reviews
    Product added to wishlist
    Product added to compare.

    This site uses Cookies.